Skip to main content
. 2018 Jul;24(7):1345–1348. doi: 10.3201/eid2407.171978

Table 2. Legionella pneumophila species PCR results from environmental samples collected on merchant vessel, Australia, 2015.

Sample type
Samples collected on vessel, by date

Dismantled showerheads
August 27
September 4
October 12
Reference laboratory testing
Reference laboratory testing
In-field testing

Reference laboratory testing
Reference laboratory testing
Total
PCR+
Total
PCR+
Total
PCR+
Total
PCR+
Total
PCR+
Cabin shower heads 6 3 36 0 12 0 29 0 32 19
Cabin faucets 14 9 33 1 12 0 29 1 NA NA
Air conditioning 4 0 NA NA NA NA NA NA NA NA
Water supply 2 0 NA NA NA NA NA NA NA NA
Others 1 1 10 1 NA NA NA NA NA NA
Total results
27
13

79
2

24
0

58
1

32
19
PCR controls
Positive, Legionella 
 DNA extract 2 2 2 2 2 2 2 2 2 2
Negative, ultrapure 
 water
6
0

16
0

5
0

12
0

6
0
*NA, not applicable; +, positive.