Skip to main content
. 2018 Jul 13;26:57. doi: 10.1186/s13049-018-0525-y

Fig. 2.

Fig. 2

Receiver operating curves of the logistic regression models for patient deterioration using various repeated vital sign measurements in 30-min intervals during the first three hours of the patient’s stay in the emergency department. The base model includes age, gender and comorbidities. Model M1 contains the base model combined with the value of the vital sign at admission, model M2 contains model M1 combined with the change of the vital sign over time, model M3 contains model M1 combined with the variability of the vital. A) the ROC curve for the base model combined with heart rate (HR). B) the ROC curve for the base model combined with mean arterial pressure (MAP). C) the ROC curve for the base model combined with respiratory rate (RR). * Base model only including patients with respiratory rate at admission (AUC .638). D) the ROC curve for the base model combined with body temperature (BT)