Skip to main content
. 2018 Jun 5;27(5):840–846. doi: 10.1177/0963689718763751

Table 3.

Parameters of Glycemic Variability from the Retrospective Continuous Glucose Monitoring System.

Indexes Control Patients Transplanted Patients P Value
HbA1c (mmol, %) 71 ± 10 (8.7 ± 1.0) 41 ± 6 (5.9 ± 0.6) 0.004*
Clarke score 5 ± 1 0 0.001*
Sensor glucose mean (mg/dL) 212 ± 47 109 ± 16 0.012*
Coefficient variation (%) 37 ± 7 13 ± 2 0.012*
Standard deviation (mg/dL) 77 ± 11 15 ± 4 0.012*
AUC (min mg/dL) 1,058 ± 235 545 ± 79 0.012*
MAGE (mg/dL) 1.2 ± 0.2 0.3 ± 0.1 0.012*
CONGA-4 94 ± 10 19 ± 8 0.012*
MODD (mg/dL) 66 ± 40 11 ± 4 0.037*
HBGI 19.8 ± 7.6 0.7 ± 0.5 0.012*
LBGI 5.9 ± 4.1 1.2 ± 1.1 0.022*
BGRI 18 ± 7 1 ± 1 0.012*
ADRR 71 ± 9 10 ± 4 0.012*
J index 86 ± 31 16 ± 5 0.012*
Time in range (%) 31 ± 15 99 ± 2 0.008*

Note: Glucose values are expressed in mg/dL. Data are expressed as mean ± standard deviation. Abbreviations: AUC, the area under the curve of glycemic values; MAGE, the mean amplitude of glucose excursion; CONGA-4, the continuous overall net glycemic action of the previous 4 h; MODD, the mean of daily differences; HBGI, the high blood glucose index; LBGI, the low blood glucose index; ADRR, the average daily risk range; BGRI, the blood glucose risk index.

*Indicates P value ≤ 0.05.