Table 3.

Quantitative validation metrics for simulations of epicardial potentials produced during ischemia using source models generated from both subject-specific ischemic zones (Zone-Based) and measured intracardiac potentials from needle electrodes (Needle-Based).10

Statistical Measure Experiment 1A Zone-Based Experiment 1A Needle-Based Experiment 2A Zone-Based Experiment 2A Needle-Based
PCC 0.86 0.73 0.84 0.68
RMSE 1.20 mV 1.54 mV 0.80 mV 0.79 mV
AEmax 7.78 mV 7.61 mV 4.56 mV 5.43 mV
*AE% 15.1% 52.6% 12.3 % 15.0%

Statistical Measure Experiment 1B Zone-Based Experiment 1B Needle-Based Experiment 2B Zone-Based Experiment 2B Needle-Based

PCC 0.81 0.59 0.68 0.47
RMSE 0.59 mV 0.88 mV 0.94 mV 0.78 mV
AEmax 3.27 mV 4.58 mV 6.54 mV 6.13 mV
AE% 6.3% 21.8% 16.0% 15.1%

Statistical Measure Experiment 1C Zone-Based Experiment 1C Needle-Based Experiment 2C Zone-Based Experiment 2C Needle-Based

PCC 0.65 0.44 0.65 0.49
RMSE 0.63 mV 0.69 mV 0.90 mV 0.43 mV
AEmax 3.96 mV 3.96 mV 5.22 mV 3.47 mV
AE% 6.3% 12.6% 11.1% 6.3%
*

AE% represents the percentage of the epicardial surface with 1 mV of absolute error or greater.