Skip to main content
. 2018 Jun 24;5(7):2860–2867. doi: 10.1021/acsphotonics.8b00206

Figure 5.

Figure 5

Numerical calculations for the detection of an action potential using the parameters extracted from the experimental data of the NR presenting the highest Δλ. (a) Detection confidence level (blue) and false positive probability (red) as a function of the threshold in units of σ. (b) False positive probability as a function of the detection confidence level for when a single (blue) or three (red) NRs are considered.