Skip to main content
. 2018 Jul 19;22:2331216518787276. doi: 10.1177/2331216518787276

Table 1.

CI Subject Demographics.

Subject Age Gender Ear tested Device Strategy Bilateral CI Contralateral hearing aid Duration of deafness (years) Duration of CI use (years) Etiology
R94 56 M R CI512 ACE No Yes 10 5 Unknown
R96 75 M R CI512 ACE No No 2 5 Genetic
R47 61 M L CI24RE (CA) FAST Yes No 0.5 10 Meniere’s
R119 45 M L CI512 ACE Yes No 1 4 Genetic
R56 69 F L CI24RE (CA) ACE No Yes 5 8 Unknown
R116 83 M L CI24RE (CA) ACE Yes No 7 3 Unknown
R04 68 M L CI24R (CA) ACE Yes No 1 11 Otosclerosis
R127 53 F L CI512 ACE Yes No 17 4 Unknown
R45 53 F L CI24R (CA) ACE Yes No 0.5 11 Cogan’s
R125 52 M L CI422 ACE No No 2 2 Sudden SNHL
R15 76 F L CI24R (CA) ACE No No 1 11 Unknown
R95 85 M L CI512 ACE No Yes 10 5 Failed middle ear implant
R19 79 M R CI24R (CA) ACE No No 5 11 Noise exposure
R87 71 M L CI24RE (CA) ACE No Yes 3 6 Unknown
R59 48 F R CI24RE (CA) ACE No Yes 8 8 Muckle–Wells
R134 54 F R CI422 ACE Yes No 52 2 Malformation
R17 54 M R CI24R (CS) ACE No No 1 12 Genetic
R76 66 M R CI24RE (CA) ACE Yes No 10 7 Infections
R68 51 M L CI24RE (CA) FAST Yes No 17 7 Unknown
R129 39 F R CI24RE (CA) FAST No Yes 3 4 Otosclerosis

Note. ACE = Advanced Combination Encoder; CI = cochlear implant; FAST = Fundamental Asynchronous Stimulus Timing; SNHL = sensorineural hearing loss.