Skip to main content
. Author manuscript; available in PMC: 2019 Mar 1.
Published in final edited form as: Hear Res. 2017 Dec 28;360:76–91. doi: 10.1016/j.heares.2017.12.017

Figure 2.

Figure 2.

Examples of ion channel currents as implemented at the NEURON level. The voltage dependent currents as measured in voltage clamp from a simple point cell were used to demonstrate the high-voltage activated (gKHT; panels A1), low-voltage activated (gKLT; panel B1) and transient potassium (gKA; panel C1) currents from the model of Rothman and Manis (2003c). The middle row (A2, B2, C2) shows the command potentials, and the lower row (A3, B3, C3) shows the steady state (open circles) and maximum (solid triangles) currents for each type of conductance.