Table 4.

Paired Comparisons of subharmonic aided pressure estimation (SHAPE) in left ventricle (LV) and the manometer pressures for all canines.

Difference (mmHg) (SHAPE – manometer pressure
95% Confidence Interval of the Difference (mmHg)
Significance (2-tailed)
Mean Standard deviation Standard error of mean Lower Upper
M-LVDP* 1.26 1.49 0.75 −1.11 3.64 0.18
LVDmin −0.03 1.81 0.91 −2.92 2.85 0.97
LVEDP 1.86 6.16 3.08 −7.94 11.67 0.59
LVPSP§ 1.37 1.59 0.79 −1.16 3.90 0.18
*

mean LV diastolic pressure,

minimum LV diastolic pressure,

LV end diastolic pressure,

§

LV peak systolic pressure