Skip to main content
. 2018 Jul 11;12:851. doi: 10.3332/ecancer.2018.851

Table 2. Evaluation results.

Measurement Description Result
Functional suitability
Functional completeness Degree to which the set of functions covers all the specified tasks and user objectives. Seven requirements/seven completed
Functional correctness Degree to which a product or system provides the correct results with the needed degree of precision. True
Functional appropriateness Degree to which the functions facilitate the accomplishment of specified tasks and objectives. True
Compatibility
Coexistence Degree to which a product can perform its required functions efficiently while sharing a common environment and resources with other products True
Interoperability Degree to which two or more systems, products or components can exchange information and use the information that has been exchanged. True
Security
Confidentiality Degree to which a product or system ensures that data are accessible only to those authorised to have access True
Authenticity Degree to which the identity of a subject or resource can be proved to be the one claimed. True
Performance efficiency
Time behaviour Degree to which the response and processing times and throughput rates of a product or system, when performing its functions, meet requirements. Average response time: 1,310.57 ms
Resource utilisation Degree to which the amounts and types of resources used by a product or system, when performing its functions, meet requirements. Min response time: 187 ms, max response time :12,024 ms
Capacity Degree to which the maximum limits of a product or system parameter meet requirements. Network I/O: 40.24 KB/s; memory: 13.82%; CPU: 5.72%; connections: 13