Table 1. Mean levels of formaldehyde (μg m–3) measured in the personal dosimeters of the workers of a plastic laminate plant and the controls.
Indoor formaldehyde exposure levels | |||
N | Mean levels ± SE | P-value a | |
Age | |||
<42 years b | 31 | 171.9 ± 24 | |
42–49 years | 35 | 130.5 ± 19 | <0.001 |
>49 years | 29 | 77.8 ± 16 | <0.001 |
P-value for trend | 0.001 | ||
Tobacco smoking | |||
Non-smokers b | 57 | 120.1 ± 16 | |
Smokers | 38 | 139.7 ± 18 | 0.676 |
Jobs | |||
Controls b | 45 | 35.2 ± 3.4 | |
Plastic laminate plant workers | 50 | 211.4 ± 14.8 | <0.001 |
a P-values after adjusting for confounding factors.
bReference level.