Skip to main content
. 2018 Jul 26;13(7):e0201019. doi: 10.1371/journal.pone.0201019

Table 5. Diagnostic performance of the different imaging parameters using the proposed cut-offs* for the prediction of pancreatic insufficiency in CF patients.

Sensitivity (95% CI) Specificity
(95% CI)
Accuracy
(95% CI)
Cutoff
US LP 90 (56–100) 73 (50–89) 0.77 (0.61–0.94) >1.3
VP 55 (21–86) 95 (76–100) 0.87 (0.73–1) >1.8
VAS 90(56–100) 69 (48–86) 0.83 (0.69–0.96) >2.5
MRI FW/FSF 100 (69–100) 100 (86–100) 1(1–1) >1.1/0.4
ADC 89 (52–100) 100 (87–100) 0.98 (0.94–1) 677

Cutoff values were defined by highest Youden Index. ADC: Apparent diffusion coefficient, CI, confidence interval, FSF: Fat-signal fraction, FW: Fat water ratio LP/VP: Liver/pancreas and Vessel/ pancreas echo intensity ratios, MRI: Magnetic resonance imaging, US: Ultrasonography. ADC: Apparent diffusion coefficient