E. coli results in spiked milk and meat samples obtained by impedimetric immunosensors and ELISA kit.

Sample Spiked Concentration [cfu/mL] Immunosensors ELISA Kit
Scheme a [cfu/mL] Recovery [%] Scheme c [cfu/mL] Recovery [%] Scheme d [cfu/mL] Recovery [%] Found Concentration [cfu/mL] Recovery [%]
Milk 1.00 × 102 0.97 × 102 97.00 0.92 × 102 92.00 0.97 × 102 97.00 1.05 × 102 105.00
1.00 × 103 0.91 × 103 91.00 0.95 × 103 95.00 0.98 × 103 98.00 1.07 × 103 107.00
5.00 × 103 4.90 × 103 98.00 4.93 × 103 98.60 4.95 × 103 99.00 4.79 × 103 95.80
1.00 × 104 0.91 × 104 91.00 0.94 × 104 94.00 0.96 × 104 96.00 1.13 × 104 113.00
Meat 1.00 × 102 0.95 × 102 95.00 0.93 × 102 93.00 0.99 × 102 99.00 1.01 × 102 101.00
1.00 × 103 0.98 × 103 98.00 0.93 × 103 93.00 0.96 × 103 96.00 0.87 × 103 98.00
5.00 × 103 5.25 × 103 105.00 5.09 × 103 101.80 5.05 × 103 99.00 4.17 × 103 95.00
1.00 × 104 0.96 × 104 96.00 0.97 × 104 97.00 0.94 × 104 94.00 1.05 × 104 95.00