Skip to main content
. 2018 Jul 31;13:192. doi: 10.1186/s13018-018-0898-7

Fig. 3.

Fig. 3

Correlation of fracture load between actual mechanical testing and the FEA prediction using the Keller-vertebra equation with a 0.3-mm shell thickness, (mechanical load) = 1.097 × (FEA-predicted fracture load) + 710.6, R2 = 0.66, p < 0.001