Skip to main content
. 2018 Jul 13;8(7):527. doi: 10.3390/nano8070527

Table 2.

The current of the CDI system for different inter-electrode distances using 1.5 V.

Distance between Electrodes (mm) Time Required for Adsorption (min) Initial Current (mA) Stable Current (mA) Charge (C) Energy (J)
5 6 4.56 1.02 0.45 0.67
15 25 2.20 0.27 0.61 0.91
25 60 1.11 0.16 0.95 1.42