Fig 2. Examples of supported levels of detail for cell models.

Fig 2

Experimental somatic recordings (black) in response to stimulating current (blue) can be modeled with BioNet at multiple levels of resolution (as long as they are supported by or can be implemented in NEURON). Here, two extremes are shown: biophysically detailed (red) and point leaky integrate-and-fire (LIF) models (orange). Example recordings and fits are from the Allen Cell Types Database.