Skip to main content
. 2014 Nov-Dec;34(6):522–526. doi: 10.5144/0256-4947.2014.522

Table 1.

The comparison of the ultrasonographic findings of the SS tendon on the operated side with the arthroscopic findings.

US examination, SS tendon findings Arthroscopic evaluation, SS tendon findings Total Chi square SD P
None Partial tear Tendinosis Full-thickness tear

None 3 1 0 0 4 81.399 (a) 9 .0a
Partial tear 1 18 1 2 22
Tendinosis 0 1 5 0 6
Full-thickness tear 0 2 1 15 18
Total 4 22 7 17 50

In 12 cells (75.0%), a frequency less than 5 was expected. The smallest expected frequency was 0.32.
a

P<.05.

SS: Supraspinatus; US: ultrasonography.