Table 2.

Comparison of Preoperative Clinical Curvature Data and Finite Element Analysis-Generated Curvature Data for Model Verification

Preoperative clinical data Simulated K (Diopters) Preoperative model Simulated K (Diopters)
OS 41.40/43.60@ 69 41.35/43.60 @ 69
OD 41.10/42.80@ 90 41.09/42.78 @ 90