Skip to main content
. Author manuscript; available in PMC: 2019 Aug 1.
Published in final edited form as: IEEE Trans Med Imaging. 2018 Feb 9;37(8):1835–1846. doi: 10.1109/TMI.2018.2804799

Table 2.

Convolutional architecture of Net1 (for slice classification and segmentation)

Kernel size Stride Number of feature maps Output size
Input - - - 512×512
HCU 1 5×5 2 16 128×128
HCU 2 3×3 1 64 64×64
HCU 3 3×3 1 128 32×32
HCU 4 3×3 1 256 16×16
HCU 5 3×3 1 512 8×8
HCU 6 3×3 1 512 4×4