Table 4.

CFD simulation results for pre-, post-, and virtual surgery models. **Outlets 1, 2, and 3 refer to the outlet vessels as labeled in Figure 5 b).

Pre-Surgery Post-Surgery Virtual - No Dilation Virtual - With Dilation
SV Flow [ml/min] 411.6 411.6 411.6 411.6
SV Max Velocity [m/s] 0.08 0.12 0.08 0.08
SMV Flow [ml/min] 591.6 591.6 591.6 591.6
SMV Max Velocity [m/s] 0.09 0.10 0.09 0.09
Outlet 1 Flow [ml/min] 90.3 541.7 541.7 541.7
Outlet 1 Max Velocity [m/s] 0.10 0.25 0.60 0.30
Outlet 2 Flow [ml/min] 40.1 220.7 220.7 220.7
Outlet 2 Max Velocity [m/s] 0.13 0.26 0.55 0.26
Outlet 3 Flow [ml/min] 40.1 240.8 240.8 240.8
Outlet 3 Max Velocity [m/s] 0.09 0.24 0.53 0.24
Maximum Pressure [Pa] 53.5 105.3 265.1 111.1
Maximum Wall Shear Stress [Pa] 4.4 6.7 17.6 7.8