Skip to main content
. 2018 Jul 22;2018:1393641. doi: 10.1155/2018/1393641

Table 1.

Outcomes of cystometric parameters in conscious rats.

Sham BOO BOO + EGCG
Peak voiding pressure 23.54 ± 2.13 42.4 ± 1.44 55.16 ± 2.6∗#
Capacity (ml) 1.15 ± 0.31 3.33 ± 0.38 4.12 ± 0.49
Compliance (μl/cm H2O) 24.37 ± 3.12 13.17 ± 3.26 21.36 ± 2.75#
Micturition interval (min) 3.67 ± 0.64 2.07 ± 0.47 3.03 ± 1.41∗#

Significantly different versus the sham group (P < 0.05). #Significantly different versus the BOO group (P < 0.05).