Table 1.
Run | Predictors1 | Response variable | Error rate (%) | Yield (%) | Final temperature (°C) | |||
---|---|---|---|---|---|---|---|---|
XPC (s) | XSA (%) | XET (min) | Experimental SP2 | Predicted SP3 | ||||
1 | 0.4 | 40 | 7 | 23.89 ± 2.16d | 23.91 | − 0.08 | 4.65 | 20 ± 0.5 |
2 | 1 | 40 | 7 | 25.43 ± 0.42cd | 25.37 | 0.23 | 5.08 | 24 ± 0.5 |
3 | 0.4 | 100 | 7 | 24.47 ± 0.79d | 23.85 | 2.53 | 4.78 | 24 ± 0.5 |
4 | 1 | 100 | 7 | 25.87 ± 0.20d | 23.20 | 10.32 | 4.74 | 26 ± 0.5 |
5 | 0.4 | 70 | 2 | 24.55 ± 1.05cd | 24.27 | − 0.08 | 4.91 | 19 ± 0.5 |
6 | 1 | 70 | 2 | 32.60 ± 0.90b | 32.88 | − 0.08 | 6.52 | 20 ± 0.5 |
7 | 0.4 | 70 | 12 | 25.21 ± 0.96cd | 24.93 | 1.11 | 5.04 | 23 ± 0.5 |
8 | 1 | 70 | 12 | 23.98 ± 0.21d | 24.26 | − 1.16 | 4.79 | 27 ± 0.5 |
9 | 0.7 | 40 | 2 | 37.12 ± 0.70a | 36.85 | 0.72 | 7.42 | 20 ± 0.5 |
10 | 0.7 | 100 | 2 | 27.19 ± 0.56c | 27.47 | − 1.02 | 5.43 | 24 ± 0.5 |
11 | 0.7 | 40 | 12 | 24.51 ± 1.48cd | 24.23 | 1.14 | 4.90 | 21 ± 0.5 |
12 | 0.7 | 100 | 12 | 24.42 ± 0.12cd | 24.70 | − 1.14 | 4.88 | 26 ± 0.5 |
13 | 0.7 | 70 | 7 | 33.44 ± 0.74b | 33.85 | − 1.12 | 6.68 | 20 ± 0.5 |
14 | 0.7 | 70 | 7 | 33.87 ± 0.76b | 33.85 | 0.05 | 6.77 | 20 ± 0.5 |
15 | 0.7 | 70 | 7 | 34.24 ± 0.18b | 33.85 | 1.13 | 6.85 | 20 ± 0.5 |
All values are mean ± SD of three determinations by triplicate (n = 9). Different letters in each file indicate significant statistical differences between treatments (α = 0.01)
1Pulses cycle (XPC); Sonication Amplitude (XSA) and Extraction Time (XET)
2Gallic acid equivalents (mg GAE/g dry basis)
3The values were predicted using a secondary polynomial equation, R2 = 0.97. Gallic acid equivalents (mg GAE/g dry basis)