Skip to main content
Clinical Cardiology logoLink to Clinical Cardiology
. 2017 Dec 6;40(12):1227–1230. doi: 10.1002/clc.22812

Administrative billing codes accurately identified occurrence of electrical cardioversion and ablation/maze procedures in a prospective cohort study of atrial fibrillation patients

Alexa N Ehlert 1, Susan R Heckbert 2,3,4, Kerri L Wiggins 2,5, Evan L Thacker 1,✉
PMCID: PMC6086133  NIHMSID: NIHMS984136  PMID: 29214653

Abstract

Background

Administrative billing codes for electrical cardioversion and ablation/maze procedures may be useful for atrial fibrillation (AF) research if the codes are accurate relative to medical record documentation.

Hypothesis

Administrative billing codes accurately identify occurrence of electrical cardioversion and ablation/maze procedures in AF patients.

Methods

We studied adults ages 30 to 84 who experienced new‐onset AF between October 2001 and December 2004 in Group Health Cooperative (acquired by Kaiser Permanente in 2017), an integrated healthcare system in Washington state and northern Idaho. Using medical record review as the gold standard, we calculated sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) for 3 administrative billing codes for electrical cardioversion and 3 codes for AF ablation/maze procedures.

Results

Of 1953 study participants, during a mean (SD) of 1.5 (0.7) years of follow‐up after AF onset, 470 (24%) experienced electrical cardioversion and 44 (2%) experienced ablation/maze procedures, according to medical record review. For electrical cardioversion, individual codes had 7.7% to 76.4% sensitivity, >99% specificity, 83.7% to 96.5% PPV, and 77.3% to 93.0% NPV. Considering any of 3 codes (code 1 or code 2 or code 3) improved sensitivity to 84.9%. For ablation/maze, individual codes had 18.2% to 47.7% sensitivity, >99% specificity, 66.7% to 95.5% PPV, and >98% NPV. Considering any of 3 codes improved sensitivity to 84.1%.

Conclusions

Administrative billing data accurately identified electrical cardioversion and ablation/maze procedures and can be used instead of medical record review. Our findings apply to healthcare settings with available administrative billing databases.

Keywords: Atrial Fibrillation, Catheter Ablation, Current Procedural Terminology, Electric Countershock, International Classification of Diseases

1. INTRODUCTION

In atrial fibrillation (AF) patients, electrical cardioversion and AF ablation/maze procedures are important methods of restoring normal heart rhythm. For researchers studying AF prognosis and treatment, detecting the occurrence of these procedures can help characterize AF progression during follow‐up of patients. For example, among patients initially identified with an episode of paroxysmal AF who then revert to sinus rhythm, occurrence of electrical cardioversion or ablation/maze later during follow‐up would indicate that AF had recurred and required intervention. These procedures are documented in medical records but can also be ascertained from administrative billing codes for research conducted in integrated healthcare systems or health insurance databases.

Although billing codes for ablation/maze procedures have been used in several research studies,1, 2, 3, 4 few researchers have investigated their accuracy.5 Having searched the literature, we are not aware of any prior study assessing accuracy of billing codes for electrical cardioversion. Hence, the purpose of our study was to assess accuracy of electrical cardioversion and ablation/maze procedure codes in administrative billing data relative to documentation of these procedures in medical records in an integrated healthcare system.

2. METHODS

2.1. Study design and setting

We conducted a prospective observational study of an inception cohort of AF patients within Group Health Cooperative (acquired by Kaiser Permanente in 2017), an integrated healthcare system currently serving >600 000 patients in Washington state and northern Idaho. Outstanding features of Group Health as a study setting include the breadth and depth of its automated databases, which include >3.4 million current and former members, and the ability to review inpatient and outpatient medical records, permitting verification of diagnoses and procedures.

2.2. Study participants

We studied patients residing in western Washington state who experienced their first electrocardiogram‐confirmed AF episode between October 2001 and December 2004 and were age 30 to 84 years. Patients were first identified by appearance of an inpatient or outpatient International Classification of Diseases, Ninth Revision (ICD‐9) code for AF (427.31) or atrial flutter (427.32) in Group Health administrative databases. Using a standardized medical record abstraction form, abstractors trained by one of the authors (SRH) reviewed each participant's diagnosis and confirmed study eligibility by medical record review. Based on this medical record review, we included patients whose initial AF or atrial flutter episode was confirmed by 12‐lead electrocardiogram and recognized by a physician. We excluded AF that was not of new onset, perioperative AF that resolved by hospital discharge, AF that occurred after pacemaker implantation, and AF that occurred as part of a hospitalized terminal illness.

The Group Health Human Subjects Review Committee approved this study and granted a waiver of consent for participants with language or cognitive difficulty and for participants who had died. All other participants provided written consent or verbal consent by telephone. Further details of the study design, setting, and participants have been previously published.6, 7, 8

2.3. Electrical cardioversion and ablation/maze procedures

Dates and results of electrical cardioversion, AF ablation, and maze procedures documented in the medical record were obtained during medical record review for a mean (SD) of 1.5 (0.7) years following onset of the initial AF episode. For the current analysis, we queried Group Health administrative databases for dates of Current Procedural Terminology (CPT) and ICD‐9 procedure codes for electrical cardioversion, AF ablation, and maze procedures. Codes for electrical cardioversion were CPT code 92960 (elective external cardioversion) and ICD‐9 codes 99.61 (atrial cardioversion) and 99.62 (other electric countershock of heart). Codes for AF ablation/maze procedures were CPT code 93651 (supraventricular tachycardia ablation) and ICD‐9 codes 37.33 (ablation/maze–open heart) and 37.34 (ablation/maze–endovascular catheter). We captured each participant's CPT and ICD‐9 procedure codes that occurred within the time period covered by their medical record review.

2.4. Statistical analysis

We determined sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of each procedure code appearing at least once in the administrative database, relative to the corresponding procedure being documented at least once in the medical record. We also determined sensitivity, specificity, PPV, and NPV of electrical cardioversion codes considered as a group (92960 or 99.61 or 99.62 appearing at least once) and of AF ablation/maze procedure codes considered as a group (93651 or 37.33 or 37.34 appearing at least once), relative to medical record documentation.

3. RESULTS

The study population consisted of 1953 individuals with newly diagnosed AF (Table 1). Medical record review showed that 470 (24%) of those individuals experienced ≥1 electrical cardioversion, and 44 (2%) experienced ≥1 ablation/maze procedure, from AF onset to the end of medical record review.

Table 1.

Study participant characteristics

Characteristic N = 1953
Demographics
Age, y 70.5 (10.9)
Female sex 47.8
White race 92.1
Setting of initial AF diagnosis
Outpatient 37.7
Urgent care 10.5
ED 37.4
Inpatient 12.9
Other 1.5
Most severe symptom present at initial AF diagnosis
Loss of consciousness 2.1
HF 10.5
Chest pain 19.5
Shortness of breath 17.4
Mental‐status change 1.6
Dizziness 7.8
Palpitations 17.2
Other 5.3
No symptoms 18.5
Clinical characteristics
HTN 54.4
DM 15.9
BMI, kg/m2 29.6 (7.3)
CKD 33.6
History of clinical CVDa 35.6

Abbreviations: AF, atrial fibrillation; BMI, body mass index; CKD, chronic kidney disease; CVD, cardiovascular disease; DM, diabetes mellitus; ED, emergency department; HF, heart failure; HTN, hypertension.

Data are presented as % or mean (standard deviation).

a

Clinical CVD included myocardial infarction, angina, coronary revascularization, valvular heart disease, HF, stroke, carotid endarterectomy, claudication, or peripheral vascular disease procedure.

Electrical cardioversion codes had varying performance compared with medical records in terms of sensitivity, PPV, and NPV, but specificity was >99% for each code individually (Table 2). The CPT code 92960 (elective external cardioversion) had the highest PPV (96.5%), but its sensitivity was only 76.4%. The 3 codes collectively yielded improved sensitivity of 84.9%, as well as high specificity (98.4%), PPV (94.5%), and NPV (95.4%).

Table 2.

Sensitivity, specificity, PPV, and NPV of billing codes for electrical cardioversion

Billing codesa Medical Record Sensitivity Specificity PPV NPV
Yes No % 95% CI % 95% CI % 95% CI % 95% CI
CPT: 92960 Yes 359 13 76.4 72.3‐80.2 99.1 98.5‐99.5 96.5 94.1‐98.1 93.0 91.6‐94.2
No 111 1470
ICD‐9: 99.61 Yes 142 6 30.2 26.1‐34.6 99.6 99.1‐99.9 95.9 91.4‐98.5 81.8 80.0‐83.6
No 328 1477
ICD‐9: 99.62 Yes 36 7 7.7 5.4‐10.4 99.5 99.0‐99.8 83.7 69.3‐93.2 77.3 75.3‐79.1
No 434 1476
92960 or 99.61 or 99.62 Yes 399 23 84.9 81.3‐88.0 98.4 97.7‐99.0 94.5 91.9‐96.5 95.4 94.2‐96.4
No 71 1460

Abbreviations: CI, confidence interval; CPT, Current Procedural Terminology; ICD‐9, International Classification of Diseases, Ninth Revision; NPV, negative predictive value; PPV, positive predictive value.

a

Descriptions of billing codes: CPT, 29260 elective external cardioversion; ICD‐9, 99.61 atrial cardioversion; ICD‐9, 99.62 other electrical countershock of heart.

Ablation/maze procedure codes all had low sensitivity individually (<50%). However, specificity for each code was high (>99.7%), as was NPV (>98%). PPV was >95% for CPT code 93651 (supraventricular tachycardia ablation) and ICD‐9 code 37.34 (ablation/maze–endovascular catheter; Table 3). When the 3 codes were combined, sensitivity improved to 84.1%, PPV was 86.0%, and specificity and NPV remained high (>99%).

Table 3.

Sensitivity, specificity, PPV, and NPV of billing codes for ablation/maze procedures

Billing codesa Medical Record Sensitivity Specificity PPV NPV
Yes No % 95% CI % 95% CI % 95% CI % 95% CI
CPT: 93651 Yes 21 1 47.7 32.5‐63.3 99.9 99.7‐100 95.5 77.2‐99.9 98.8 98.2‐99.2
No 23 1908
ICD‐9: 37.33 Yes 8 4 18.2 8.2‐32.7 99.8 99.5‐99.9 66.7 34.9‐90.1 98.1 97.4‐98.7
No 36 1905
ICD‐9: 37.34 Yes 21 1 47.7 32.5‐63.3 99.9 99.7‐100 95.5 77.2‐99.9 98.8 98.2‐99.2
No 23 1908
93651 or 37.33 or 37.34 Yes 37 6 84.1 69.9‐93.4 99.7 99.3‐99.9 86.0 72.1‐94.7 99.6 99.2‐99.9
No 7 1903

Abbreviations: CI, confidence interval; CPT, Current Procedural Terminology; ICD‐9, International Classification of Diseases, Ninth Revision; NPV, negative predictive value; PPV, positive predictive value.

a

Descriptions of billing codes: CPT, 93651 supraventricular tachycardia ablation; ICD‐9, 37.33 ablation/maze–open heart; ICD‐9, 37.34 ablation/maze–endovascular catheter.

4. DISCUSSION

In our study of 1953 individuals with new‐onset AF, we found that using 3 electrical cardioversion billing codes together, CPT code 92960 or ICD‐9 code 99.61 or ICD‐9 code 99.62, accurately identified occurrence of electrical cardioversion. The 3 codes combined had high specificity, PPV, and NPV, along with moderately high sensitivity. Similarly, the combination of 3 ablation/maze procedure codes together, CPT code 93651 or ICD‐9 code 37.33 or ICD‐9 code 37.34, accurately identified occurrence of ablation/maze procedures. These codes had high specificity and NPV, with moderately high values for sensitivity and PPV. These findings are beneficial because they indicate that electrical cardioversion and ablation/maze procedures can be accurately identified for research without medical record review.

We recommend using administrative billing codes to identify electrical cardioversion and ablation/maze procedures based on researchers' aims. There may be circumstances when high sensitivity would need to be prioritized, in which case these codes may not yield sufficiently accurate results. However, in circumstances in which specificity, PPV, or NPV is prioritized, these codes may be sufficiently accurate to complete a data analysis. For example, in our research on AF prognosis in Group Health, we have used 3‐code combinations for both electrical cardioversion and ablation/maze procedures, due to their high PPV, to determine occurrence of these procedures during follow‐up of the cohort extending beyond the time period during which medical records were reviewed. This enabled us to extend the follow‐up time in prospective studies of AF progression in relation to clinical characteristics or medication use.6, 7

We are aware of only 1 other study that assessed accuracy of algorithms for identifying AF ablation.5 Singh et al. tested accuracy of 4 different algorithms in detecting AF ablation. They reported higher sensitivities (>86%) for each of their algorithms than we did for any of our codes or code combinations. They also reported a relatively high PPV for each algorithm (>83.5%). Furthermore, their results show excellent specificity (100%) and NPV (100%) for each algorithm. One similarity between their study and ours was that their algorithms were based on billing codes. A difference between the 2 studies was that we first identified a medical record–validated cohort of AF patients and then looked for procedure codes appearing for members of that cohort, whereas Singh et al. required that hospital diagnostic codes for AF appeared in the same hospitalizations as procedure billing codes. Though their codes yielded slightly higher accuracy than ours, both studies indicate that administrative data sufficiently identify ablation/maze procedures.

4.1. Study strengths and limitations

A potential shortcoming is that the population we studied may not be representative of the general population of the United States, as our participants were predominantly white and of slightly higher socioeconomic status than the general population. A key strength of our study was the use of data from Group Health, an integrated healthcare system. Integration of medical care with medical insurance allowed us to compare data from the same individuals by linking medical records with billing records. To the extent that administrative coding practices in Group Health are similar to practices in other administrative billing settings, our results could generalize to other integrated healthcare systems or settings with insurance billing databases, such as Medicare.

5. CONCLUSION

Administrative billing data accurately identified electrical cardioversion and ablation/maze procedures and can be used instead of medical record review. Our findings inform researchers studying electrical cardioversion and ablation/maze procedures in AF patients in integrated healthcare systems or other settings where administrative billing databases are available.

Conflicts of interest

The authors declare no potential conflicts of interest.

Ehlert AN, Heckbert SR, Wiggins KL, Thacker EL. Administrative billing codes accurately identified occurrence of electrical cardioversion and ablation/maze procedures in a prospective cohort study of atrial fibrillation patients. Clin Cardiol. 2017;40:1227–1230. 10.1002/clc.22812

Funding information This study was supported by grants R01 HL068986 and T32 HL007902 from the National Heart, Lung, and Blood Institute (NHLBI).

REFERENCES

  • 1. Ellis ER, Culler SD, Simon AW, et al. Trends in utilization and complications of catheter ablation for atrial fibrillation in Medicare beneficiaries. Heart Rhythm. 2009;6:1267–1273. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 2. Piccini JP, Sinner MF, Greiner MA, et al. Outcomes of Medicare beneficiaries undergoing catheter ablation for atrial fibrillation. Circulation. 2012;126:2200–2207. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 3. Hao SC, Hunter TD, Gunnarson C, et al. Acute safety outcomes in younger and older patients with atrial fibrillation treated with catheter ablation. J Interv Card Electrophysiol. 2012;35:173–182. [DOI] [PubMed] [Google Scholar]
  • 4. Shah RU, Freeman JV, Shilane D, et al. Procedural complications, rehospitalizations, and repeat procedures after catheter ablation for atrial fibrillation [published correction appears in J Am Coll Cardiol. 2012;59:1492]. J Am Coll Cardiol. 2012;59:143–149. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 5. Singh SM, Webster L, Calzavara A, et al. Validation of algorithms to identify invasive electrophysiology procedures using administrative data in Ontario, Canada. Med Care. 2017;55:e44–e50. [DOI] [PubMed] [Google Scholar]
  • 6. Thacker EL, Jensen PN, Psaty BM, et al. Use of statins and antihypertensive medications in relation to risk of long‐standing persistent atrial fibrillation. Ann Pharmacother. 2015;49:378–386. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 7. Thacker EL, McKnight B, Psaty BM, et al. Association of body mass index, diabetes, hypertension, and blood pressure levels with risk of permanent atrial fibrillation. J Gen Intern Med. 2013;28:247–253. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 8. Garg RK, Glazer NL, Wiggins KL, et al. Ascertainment of warfarin and aspirin use by medical record review compared with automated pharmacy data. Pharmacoepidemiol Drug Saf. 2011;20:313–316. [DOI] [PMC free article] [PubMed] [Google Scholar]

Articles from Clinical Cardiology are provided here courtesy of Wiley

RESOURCES