Comparison of the selected sample preparation procedure to extraction using the QIAamp® MinElute® Virus Spin kit followed by WGA

Virus MinElute® + WGA (average of n = 3 ± standard deviation) Optimized procedure (average of n = 4 ± standard deviation) Fold change in detection
EBV 0.36 ± 0.15% 0.34% ± 0.10 0.94
RSV 0.0012 ± 0.0007% 0.0076% ± 0.0021 6.3
FeLV 0.0022 ± 0.0014% 0.036% ± 0.008 16
Reo3 0.000045 ± 0.000038% 0.38% ± 0.14 8400

The selected procedure, which involved the dual extraction strategy using both Invitrogen PureLink™ Virus RNA/DNA kit and the Wako DNA Extractor® kit with the RNase A digestion and the double-stranded DNA synthesis, was compared against the QIAGEN QIAamp® MinElute® Virus Spin kit followed by whole-genome amplification (WGA). Reported values are an average of at least three replicates with their standard deviation