Table 3. Cochrane Risk of Bias.

Name Random sequence Allocation concealment Blinding of participants and personnel Blinding of outcome assessment Incomplete outcome data Reporting bias
Byun et al [12] Not reported Not reported Blinded Not reported No Not reported
Unclear Unclear Low risk Unclear Low Risk Unclear
Lee et al [8] Central randomization with computer generated codes Not reported Blinded (complete) Not reported No Not reported
Low risk Unclear Low risk Unclear Low Risk Unclear
Corte et al [6] Central randomization with computerized algorithm No Single arm blinded* Not reported No Not reported
Low risk High risk Low risk Unclear Low risk Unclear
Brouwer et al [11] Not reported Not reported Not reported Yes No Not reported
Unclear Unclear Unclear Low risk Low risk Unclear
Rondonotti et al [10] Central randomization using computer generated list Randomization list Single arm blinded* Not reported No Not reported
Low risk Low risk Low risk Unclear Low risk Unclear
Ristnikankre et al [9] Block randomization using sealed envelopes Sealed and coded envelopes Blinded (complete) Not reported No Not reported
Low risk Low risk Low risk Unclear Low risk Unclear
Santos et al [7] Web generated Sealed envelopes Blinded Yes No Not reported
Low risk Low risk Low risk Low risk Low risk Unclear

*Administering nurse not blinded.