Table 2. EPR fit parameters derived from the best fits to the Hamiltonian (1) of the perpendicular mode spectra of the gadolinium powder samples at 2% molar concentration in the respective yttrium hosts. The off-diagonal sixth order terms could not be reliably included in the fit for 1Y0.98Gd0.02.

1Y0.98Gd0.02 2Y0.98Gd0.02 1Y0.98Gd0.02 2Y0.98Gd0.02
g 1.9865(3) 1.9880(2) 1.979(1) 1.984(1)
g 1.98552(4) 1.98690(7) 1.9862(8) 1.9843(1)
B 0 2 /cm–1 3.2378(5) × 10–2 3.0553(5) × 10–2 8.8(1) × 10–3 1.071(4) × 10–2
B 0 4 /cm–1 –2.605(4) × 10–4 –2.480(2) × 10–4 –2.0(1) × 10–4 –2.04(3) × 10–4
B 0 6 /cm–1 –2.8(7) × 10–8 4(2) × 10–8 –1(6) × 10–7 –5(5) × 10–7
B +4 4 /cm–1 1.4(5) × 10–6 1.4(2) × 10–6 1.9(3) × 10–5 6(6) × 10–6
B +4 6 /cm–1 1.62(5) × 10–6 2.0(3) × 10–7 N/A –1.3(7) × 10–6
B –4 6 /cm–1 –6.1(2) × 10–7 3.6(3) × 10–7 N/A –2(3) × 10–7