Skip to main content
. Author manuscript; available in PMC: 2022 May 1.
Published in final edited form as: Int J Radiat Oncol Biol Phys. 2018 Jan 6:S0360-3016(17)34527-3. doi: 10.1016/j.ijrobp.2017.12.290

Table 2.

Treatment planning and dosimetric information for SBRT studies included in liver toxicity dose-volume analysis (all studies prescribed to PTV)

Investigator Fractions (n) Total dose range (Gy) Imaging modalities Target margins Prescription definition Motion management Liver planning guidelines
Barney et al (24), 2012 3, 5 45–60 CT, MRI GTV = CTV; ITV = CTV + motion margin using 4DCT; PTV = ITV + nonuniform 5-mm margin Isodose line covers PTV based on tumor volume and proximity of OARs Gating, abdominal compression ≥700 cm3 to ≤21 Gy
Tse et al (13), 2008 6 24–54 kV fluoroscopy, CT, MRI CTV = GTV + 8 mm within liver; PTV = CTV + individualized margin (minimum 5 mm) Isodose line covers PTV based on limiting RILD risk Breath hold, abdominal compression Based on Veff
Vautravers-Dewas et al (25), 2011 3, 4 40, 45 CT, MRI CTV = GTV + 5 mm; PTV = CTV + 3 mm 80% Isodose line covers PTV CyberKnife respiratory tracking system with fiducial markers V21Gy <33%
Huang et al (22), 2012 4, 5 25–48 CT With fiducial markers: PTV = GTV + 0– 8 mm (increased to 8–20 mm in caudocephalad direction if no fiducial markers) 70%–83% Isodose line covers PTV CyberKnife respiratory tracking system with fiducial markers, abdominal compression ≥700 cm3 to ≤15 Gy
Kang et al (21), 2012 3 42–60 CT ITV = GTV + motion margin using slow CT; PTV = ITV + 4 mm in longitudinal direction and 2 mm in all other directions SBRT doses prescribed at isodose line (70%–80% of maximum dose) covering ≥97% of PTV Abdominal compression, CyberKnife respiratory tracking system with fiducial markers ≥700 cm3 to ≤17 Gy
Goodman et al (10), 2010 1 18–30 CT, MRI, PET/CT ITV = GTV + motion margin using 4DCT; PTV = ITV + 3–5 mm for patients with 4DCT; PTV = ITV + 5–10 mm for patients with no 4DCT 65%-90% isodose covering PTV CyberKnife respiratory tracking system with fiducial markers ≥700 cm3 to ≤15 Gy
Lee et al (11), 2009 6 27.7–60 kV fluoroscopy, CT, MRI CTV = GTV + 8 mm within liver; PTV = nonuniform expansion around GTV and CTV based on individual patient tumor motion and reproducibility of immobilization (≥5 mm) Isodose line covering PTV based on limiting RILD risk (maximum dose of 140% within target) Active breathing control, abdominal compression Based on Veff
Andolino et al (14), 2011 3, 5 CP: A, 44 (30–48); B, 40 (24–48) Dual-phase CT PTV = GTV + 5 mm radially and + 10 mm superoinferiorly 80% Isodose line covering PTV Abdominal compression CP A: 1/3 to ≤10 Gy and ≥500 cm3 to <7 Gy; CP B: 1/3 to ≤18 Gy and ≥500 cm3 to <12 Gy
Bujold et al (12), 2013 6 24–54 CT, MRI CTV = GTV + 5–8 mm within liver; PTV = nonuniform expansion around CTV based on individual patient tumor motion and reproducibility of immobilization (≥5 mm) Isodose line covering PTV based on limiting RILD risk Active breathing control, abdominal compression Based on Veff
Son et al (20), 3 30–39 CT PTV = GTV + 3–5 mm PTV enclosed by 70%–85% isodose line Breath hold + CyberKnife respiratory tracking system with fiducial markers V20Gy ≤50%
Barney et al (26), 2013 1, 3, 5 28–60 CT, PET/CT ITV = GTV + motion margin using 4DCT; PTV = ITV + 5 mm 95% coverage of PTV with prescription isodose line NA NA
Bae et al (23), 2013 3, 4, 5 30–60 CT, MRI, PET/CT GTV = CTV; PTV = CTV + 4 mm in longitudinal direction and 2 mm in all other directions 56%–83% Isodose line of maximum dose in CyberKnife and 91%–100% in RapidArc to cover ≥95% of PTVs NA ≥700 cm3 to ≤17 Gy

Abbreviations: CT = computed tomography; CTV = clinical target volume; GTV = gross tumor volume; ITV = internal target volume; MRI = magnetic resonance imaging; NA = not available; PET = positron emission tomography; PTV = planning target volume.