Table 2.
The performance of circulating miR-222-3p and miR-221/.222 Ct ratio for predicting isolated low HDL-C phenotype
| Models | AUC (95%CI) | p value | Cut-off value | Specificity | Sensitivity |
|---|---|---|---|---|---|
| miR-222-3p | 0.648 (0.566, 0.730) | < 0.001 | 0.559 | 0.837 | 0.432 |
| The miR-221-3p/miR-222-3p ratio | 0.678 (0.598, 0.758) | < 0.001 | 0.562 | 0.767 | 0.568 |
| Clinical model | 0.771 (0.702, 0.840) | < 0.001 | 0.462 | 0.698 | 0.761 |
| Clinical model + miR-222-3pa | 0.816 (0.754, 0.879) b | < 0.001 | 0.413 | 0.663 | 0.879 |
| Clinical model + miR221-3p/miR-222-3p ratioa | 0.813 (0.751, 0.876) b | < 0.001 | 0.423 | 0.686 | 0.818 |
AUC area under the curve. Best threshold of Cut-off value were estimated using youden method. a The AUC, sensitivities and specificities of the combination model of miR-222-3p and clinical model was compared with that of clinical model. bp < 0.05