Skip to main content
. 2018 Aug 13;77(9):793–802. doi: 10.1093/jnen/nly056

TABLE 1.

Immunohistochemical Methods Tested

Primary Antibody Epitope Exposure Signal Development
Nantes
  • p-synuclein monoclonal

  • MJF-R13 (8-8) ab168381

  • Abcam*

  • 1:10 000 (17)

  • Leica, Proteinase K for 15 minutes

  • (Bond Enzyme Pretreatment Kit)

Leica, peroxidase blocking with Bond Enzyme Pretreatment Kit; mixed DAB Refine
RICM
  • a-synuclein monoclonal

  • 5C12 (41)

  • Prothena

  • 1 µg/mL

  • Ventana§ Protease 1

  • 36°C, 12 minutes

Ventana Benchmark Ultra§; Optiview DAB IHC Detection Kit
*

Abcam, Cambridge, UK.

Leica Biosystems, Kassel, Germany.

Prothena Biosciences, Dublin, Ireland.

§

Ventana Medical Systems, Tucson, Arizona.

p-synuclein = α-synuclein phosphorylated at serine 129; a-synuclein = α-synuclein unmodified form; DAB = 3,3′ di-aminobenzidine. All slides were counterstained with hematoxylin. See Supplementary Data Materials for full description.