Skip to main content
. Author manuscript; available in PMC: 2019 Oct 1.
Published in final edited form as: Magn Reson Med. 2018 Feb 28;80(4):1429–1439. doi: 10.1002/mrm.27131

Table 2.

T and its fitting standard errors (ms) of quadriceps tendon, patellar tendon, ACL, PCL, meniscus, patellar cartilage and muscles in six in vivo human knee samples as well as their average and standard deviation values (ms).

In vivo knee # 1 # 2 # 3 # 4 # 5 # 6 Average
Quadriceps tendon 13.6±0.6 13.4±1.1 13.6±1.0 14.9±1.3 13.7±1.0 12.9±1.2 13.9±0.7
Patellar tendon 9.3±0.5 9.3±0.4 9.4±0.3 9.6±0.7 9.4±0.5 11.3±0.6 9.7±0.8
ACL 35.0±4.5 37.3±3.8 33.4±3.5 37.5±5.6 36.1±3.9 30.0±3.0 34.9±2.8
PCL 21.5±1.9 22.9±1.7 21.2±2.0 22.6±1.7 22.5±1.2 19.0±1.5 21.6±1.4
Meniscus 23.0±1.6 21.3±1.4 26.2±1.9 21.4±1.7 21.5±1.1 21.7±1.6 22.5±1.9
Patellar cartilage 42.3±6.5 47.7±6.9 47.3±7.5 42.5±6.6 43.5±5.9 44.1±6.2 44.5±2.4
Muscle 43.7±4.8 42.0±4.7 41.8±4.2 43.7±4.8 44.5±3.2 43.5±4.4 43.2±1.1