Skip to main content
. 2018 May 11;5(4):118–123. doi: 10.1049/htl.2017.0026

Table 2.

Results of suggested algorithm correlated with other studies for macular oedema detection

Author Techniques Sensitivity, % Specificity, % Accuracy, % Number of images Dataset used
Tariq et al. [14] filter bank and GMM 97.2 98.32 97.89 1281 STARE & MESSIDOR
Medhi et al. [15] image processing 98.05 98.86
Deepak and Sivaswamy [16] rotational asymmetric motion pattern 95 90 400 MESSIDOR
Lim et al. [17] marker-controlled watershed transform
80.9 90.2 88 MESSIDOR
Rahim et al. [18] fuzzy image processing 86.8 100 93 600 Novel
suggested method image processing 97.75 100 98.86 89 DIARETDB1