Skip to main content
. 2018 Aug 21;8:12517. doi: 10.1038/s41598-018-31035-y

Figure 7.

Figure 7

Depth-controlled indentation profiles. (a) Oscillatory ramp loading profile at 5.62 Hz oscillation frequency and (b) equilibrium frequency sweep profile between 1–10 Hz frequency range with both oscillation amplitudes of 0.2 μm.