Table 1.
Entry | I+ Salta |
18F-fluoride [18F]F−X+ |
Method |
T
(°C) |
t
(min) |
Solventb | TEMPO & H2Ob |
Product | Yield (%)c |
n |
---|---|---|---|---|---|---|---|---|---|---|
1 | 5 | [18F]F−K+ | manual | 150 | 10 | MeCN | – | [18F]6 | NR | 2 |
2 | 5 | [18F]F−K+ | manual | 150 | 10 | DMF | – | [18F]6 | 3 ± 2 | 2 |
3 | 5 | [18F]F−TBA+ | manual | 150 | 10 | DMF | – | [18F]6 | Trace | 2 |
4 | 5 | [18F]F−Cs+ | manual | 150 | 10 | DMF | – | [18F]6 | 9 ± 2 | 2 |
5 | 5 | [18F]F−Cs+ | manual | 150 | 5 | DMF | + | [18F]6 | 51 ± 5 | 3 |
6 | 5 | [18F]F−Cs+ | manual | 130 | 5 | DMF | + | [18F]6 | 31 ± 5 | 3 |
7 | 5 | [18F]F−Cs+ | manual | 120 | 5 | DMF | + | [18F]6 | 28 ± 3 | 3 |
8 | 5 | [18F]F−Cs+ | manual | 150 | 15 | DMF | + | [18F]6 | 43 ± 5 | 2 |
9 | 5 | [18F]F−Cs+ | manual | 150 | 25 | DMF | + | [18F]6 | 30 ± 5 | 2 |
10 | 11 | [18F]F−Cs+ | manual | 150 | 5 | DMF | + | [18F]22 | 16 ± 5 | 5 |
11 | 11 | [18F]F−Cs+ | manual | 150 | 15 | DMF | + | [18F]22 | 11 ± 4 | 3 |
12 | 11 | [18F]F−Cs+ | automated | 150 | 5 | DMF | + | [18F]1 | 7.0 ± 3.5 d | 13 |
13 | 21 | [18F]F−Cs+ | automated | 150 | 5 | DMF | + | [18F]2 | 8.0 ± 3.5 e | 12 |
Amount of diaryliodonium salt precursor used was 4-6 mg.
Reaction solvent (MeCN or DMF; 500 μL) prepared without (−) or with (+) 1 mg TEMPO and 10 μL of H2O.
Progress of the reaction and yields for manual reactions were analyzed by radio-TLC (developing solvent: ethylacetate/hexane = 30:70, vol/vol).
Yield of the isolated pure product [18F]1 by semipreparative column (Phenomenex Synergi 10μ Hydro-RP 80A, 250×10 mm) using HPLC (5% EtOH in 40 mM NH4OAc buffer, λ=254 nm, 4.0 ml/min).
Yield of the isolated pure product [18F]2 by semipreparative column (Phenomenex Synergi 10μ Hydro-RP 80A, 250×10 mm) using HPLC (3.5% EtOH in 40 mM NH4OAc buffer, λ=254 nm, 4.0 ml/min).