Skip to main content
. Author manuscript; available in PMC: 2018 Sep 5.
Published in final edited form as: IEEE Trans Med Imaging. 2018 Feb 26;37(9):2010–2021. doi: 10.1109/TMI.2018.2809641

Table VI.

SPECKLE STATISTICS FOR IN VIVO SCANS

Fig. 11 (a–c) Fig. 11 (d–f)
Parameter DAS CF DNN DAS CF DNN
CR (dB) 6.5 20.7 25.7 1.2 8.6 9.5
CNR (dB) −0.4 −0.3 4.5 −15.9 −5.2 −1.5
Speckle SNR 2.03 1.07 1.75 1.83 0.96 1.44