Table 2.

Comparisons of classification-based accuracy between the SVM and CNN classifiers for six subregions of ILD

Study Classification accuracy (%) p value
SVM CNN
intra.G 90.06 ± 1.99 96.06 ± 1.61 < 0.001
intra.S 89.01 ± 2.20 96.11 ± 1.19 < 0.001
integ 88.07 ± 1.63 95.12 ± 1.91 < 0.001
inter.G2S 77.26 ± 3.08 86.13 ± 2.28 < 0.001
inter.S2G 77.03 ± 3.42 85.04 ± 1.91 < 0.001