Skip to main content
. 2018 Aug 27;56(9):e00531-18. doi: 10.1128/JCM.00531-18

TABLE 5.

Performance of FluoroType MTBDR for detection of MDR-TB from smear-positive and smear-negative sputum specimens when using Sanger sequencing and GenoType MTBDRplus as reference methodsa

Specimen Sensitivity
Specificity
Positive LR (95% CI) Negative LR (95% CI) No. of indeterminate results
% (95% CI) No. of specimens positive/total no. tested % (95% CI) No. of specimens positive/total no. tested
All (n = 315) 99.3 (95.8–100) 148/149 100 (97.2–100) 166/166 Infinity (NaN–infinity) Infinity (NaN–infinity) 7
Sputum smear positive (n = 228) 99.1 (94.3–100) 108/109 100 (96.1–100) 119/119 Infinity (NaN–infinity) 0.09 (0.001–0.06) 4
Sputum smear negative (n = 87) 100 (89.1–100) 40/40 100 (90.6–100) 47/47 Infinity (NaN–infinity) Infinity (NaN–infinity) 3
a

Definitions of abbreviations: ind, indeterminate; CI, confidence interval; LR, likelihood ratio; NaN, the calculation could not be performed because the values entered included one or more instances of zero.