Skip to main content
. 2018 Aug 19;20:537–542. doi: 10.1016/j.nicl.2018.08.024

Table 2.

Summary of best multivariate models and results from model validation.

FET PET CE-MRI Combined
Included features PET_Volume T1_stdValue T1_LZE
PET_GLNUr T1_Volume T1_GLNUz
PET_RLNU T1_Compacity T1_ZLNU
PET_LZHGE T1_RLNU T1_DWT3_GLNUz
PET_GLNUz T1_LoG_ZLNU PET_SRE
Accuracy 83% 81% 89%
Sensitivity 88% 67% 85%
Specificity 75% 90% 96%
AUC 0.91 0.85 0.96
Model validation
LOOCV Accuracy 72% 71% 83%
Sensitivity 77% 81% 85%
Specificity 65% 57% 80%
AUC 0.75 0.74 0.86
5-fold CV Accuracy 74% 77% 80%
Sensitivity 81% 84% 85%
Specificity 65% 67% 75%
AUC 0.76 0.75 0.85
10-fold CV Accuracy 76% 74% 83%
Sensitivity 85% 81% 81%
Specificity 65% 62% 85%
AUC 0.79 0.77 0.84

AUC: Area under the receiver-operating characteristics curve; CI: Confidence interval; CV: Cross-validation; DWT3: Discrete 3-dimensional wavelet transformation; GLNUr: Grey-level non-uniformity for run; GLNUz: Grey-level non-uniformity for zone; LoG: Laplacian-of-Gaussian filter; LOOCV: Leave-one-out cross-validation; LZE: Long-zone emphasis; LZHGE: Long-zone high grey-level emphasis; RLNU: Run length non-uniformity; ZLNU: Zone length non-uniformity.