Skip to main content
. 2018 Aug 14;8(8):155. doi: 10.3390/brainsci8080155

Table 2.

Characteristics of studies and case reports on transcranial direct current stimulation (tDCS) use in pregnancy.

Author/Journal Type/Number of Participants/Age/Diagnosis Electrode Placement/Electrode Size Stimulation Parameters Results Adverse Events/Side Effects/Examinations in Fetus and Mother
Sreeraj et al.
Brain Stimulation 2016
[13]
Case report
n = 1
23 years
Recurrent depression
Anode: F3,
Cathode: F4
25 cm2
2 mA, 30 min/day, 10 days At the end of the follow-up-phase, HAMD changed from 18 to 5 points and HAMA changed from 32 before intervention to 6 after intervention, both showing a remission. The patient tolerated tDCS well without any adverse event. In 3 out of the total 10 tDCS sessions, side effects were reported: during the fade-in phase transient, mild burning sensations at the site of application and phosphenes. No specific examinations in fetus/mother.
Strube et al.
J Clin Psychopharmacol,
2016
[31]
Case report
n = 1
36 years
Schizophrenia
Anode: F3,
Cathode: Tp3
2 mA, 2 × 20 min/day, 10 days Based on the Calgary Depression Scale in Schizophrenia (CDSS), depression symptoms associated with schizophrenia were reduced by 41% although improvement of auditory hallucinations was the primary target. tDCS was well tolerated with no reported or noticeable adverse events or side effects.
Fetal examination via standard ultrasound at follow-up (gestational week 35) revealed no abnormalities. Normal sonography and delivery 1 week before calculated date.
Palm et al.
Clin Neurophysiol, 2017
[30]
Pilot Study (with target sample of n = 10)
First results: n = 3
23, 28 and 32 years
(Recurrent) Depression
Anode: F3,
Cathode: F4
2 mA, 2 × 30 min/day for 10 days and 1 × 30 min/day for 10 days No statistically significant changes could be observed yet. One patient achieved remission. tDCS was well tolerated and no adverse events occurred. No specific examinations in the fetus/mother.

HAMD: Hamilton Depression Rating Scale; HAMA: Hamilton Anxiety Rating Scale; electrode placements according 10–20 EEG system: F3/F4: left/right dorsolateral prefrontal cortex; Tp3: left temporoparietal junction.