Skip to main content
. Author manuscript; available in PMC: 2018 Sep 5.
Published in final edited form as: Hear Res. 2017 Apr 12;350:45–57. doi: 10.1016/j.heares.2017.04.005

Table 1.

Electrode array information and study sample size.

Array Active Contacts Active Array Length (mm) Insertion Depth (mm) Insertion Approach Earliest Implant Date (yr) NTot NIncl NECAP
S8M 6 4.05 10.0 C 2001 12 11 10
S8RE 6 4.05 10.0 C 2005 12 12 12
S12 10 5.40 10.0 C 2008 15 15 11
L24 22 14.50 17.5–18.0 C/RW 2009 41 32 13
422 22 20.00 20.0–25.0 C/RW 2012 63 15 2

   Total 143 85 48

NTot: Total number of participants identified in the query. NIncl: Number of participants included in the data set. NECAP: Subset of included participants with ECAP data in addition to audiometric threshold and impedance data. All other participants had both behavioral audiometric thresholds and impedance data available for review. C: Cochleostomy. RW: Round window.