Skip to main content
. 2018 Aug 30;13:2695–2705. doi: 10.2147/COPD.S165780

Table 1.

Characters of included studies

Study source Study design Study population Gender (m/f) Number of participants COPD diagnosis FENO measurement
Kanazawa et al,16 1998 CS Japan 21/0 21 ATS Chemiluminescence analyzer (CLM-500; Shimazu; Kyoto, Japan)
Rutgers et al,23 1998 CS the Netherlands 25/7 32 Doctor-diagnosis Chemiluminescence analyzer (CLD 700 AL, ECO physics, Dürnten, Switzerland)
Agusti et al,29 1999 CS Spain 27/0 27 Doctor-diagnosis Chemiluminescence analyzer (Dasibi Environmental, Glendale, CA, USA)
Corradi et al,28 1999 CS Italy 32/18 50 BTS Chemiluminescence NO analyzer (model 42S; Thermo Environmental Instruments Inc, Franklin, MA, USA)
Clini et al,11 2000 CS Italy 17/2 19 ATS Chemiluminescence analyzer (LR 2000 series; Logan Research; Kent, UK)
Delen et al,13 2000 CS America NA 77 Doctor-diagnosis Chemiluminescence (model 280; Sievers Instruments; Boulder, CO, USA)
Papi et al,20 2000 CS Italy 24/5 29 ERS Chemiluminescence analyzer (NOA 280; Sievers)
Montuschi et al,19 2001 CS United Kingdom 27/25 52 BTS Chemiluminescence analyzer (model LR 2000; Logan Research; Rochester, UK)
Hogman et al,15 2002 CS Sweden NA 60 Doctor-diagnosis 280 chemiluminescence analyzer (Sievers)
Zietkowski et al,27 2005 CS Poland 58/29 87 ERS Chemiluminescence technique (Sievers 280i NO analyzer, Sievers)
Brindicci et al,10 2005 CS United Kingdom 27/24 51 GOLD Chemiluminescence analyzer (NIOXH; Aerocrine AB, Stockholm, Sweden)
Ziora et al,26 2007 CS Poland 51/12 63 GOLD Chemiluminescent NO analyzer (model 280, Sievers Instruments)
Liu et al,17 2007 CS Australia NA 176 Doctor-diagnosis Chemiluminescent NO analyzer (Dasibi Environmental Corp.)
de Laurentiis et al,12 2008 CS Italy NA 69 GOLD Electrochemical FENO device (NIOX MINO, Aerocrine)/chemiluminescence analyzer (NOA, Sensormedics, Milano, Italy)
Beg et al,31 2009 CS Saudi Arabia 39/0 39 Doctor-diagnosis Chemiluminescence analyzer (SERES, Aix-en-Provence, France)
Lehouck et al,33 2010 CC Belgium 121/30 151 GOLD Chemiluminescence analyzer (NIOX, Flex; Aerocrine AB)
Rouhos et al,22 2011 CS Finland 18/21 39 Doctor-diagnosis Chemiluminescence analyzer (Sievers 270B, Sievers)
Maricic et al,18 2013 CS Croatia NA 100 GOLD NA
Sun et al,25 2013 CS People’s Republic of China 35/10 45 CMA The 4540-1999b portable nitric oxide gas detector (Interscan Corporation, Simi Valley, CA USA)
Hirano et al,14 2013 CS Japan 24/12 36 GOLD Chemiluminescence-based NO analyzer NA-623N, (Chest Co. and Kimoto Electric Co., Tokyo, Japan)
Moussa et al,32 2014 CC Tunisia 45/0 45 Doctor-diagnosis Electrochemical analyzer (Medisoft, Dinant, Belgium)
Rawy and Mansour,21 2015 CS Egypt 61/29 90 Doctor-diagnosis Niox Mino analyzer (Aerocrine AG)
Santini et al,30 2016 CS Italy 67/22 99 GOLD NIOX system (Aerocrine)
Shrestha et al,24 2017 CS Nepal 91/121 212 GOLD Handheld Bedfont NO breath point-of-care device (Bedfont Scientific Ltd, Maidstone, Kent, UK, registered in England and Wales)

Abbreviations: ATS, American Thoracic Society criteria; BTS, British Thoracic Society guidelines; CC, case–control study; CMA, Chinese Medical Association guidelines; COPD, chronic obstructive pulmonary disease; CS, cross-sectional study; ERS, European Respiratory Society criteria; FENO, fractional exhaled nitric oxide; GOLD, Global Initiative for Obstructive Lung Disease; NA, not available.