Skip to main content
. 2018 Mar 3;30(3):228–233. doi: 10.1016/j.joco.2018.01.005

Table 2.

Contralateral comparison of endothelial cell parameters was measured by specular microscope between keratoconus (KCN) eyes with Vogt's striae and those without Vogt's striae.

Parameter With Vogt's striae
Without Vogt's striae
Mean difference P-value
Mean ± SD Range Mean ± SD Range
CCT (μm) 459.28 ± 35.49 378.00 to 540.00 481.38 ± 34.14 397.00 to 548.00 −22.10 ± 30.32 <0.001b
ECD (cell/mm2) 2968.34 ± 276.65 2166.00 to 3507.00 2980.05 ± 253.30 2345.00 to 3520 −11.72 ± 165.01 0.618b
CV (%) 32.50 ± 5.40 18.00 to 51.00 32.97 ± 4.07 24.00 to 43.00 −0.47 ± 4.51 0.467a
HEX (%) 51.88 ± 13.57 17.00 to 75.00 53.24 ± 9.31 31.00 to 74.00 −1.36 ± 14.22 0.658a

CCT: Central corneal thickness, ECD: Endothelial cell density, CV: Coefficient of variation, HEX: Hexagonal cells, SD: Standard deviation. There were no missing data. P-value <0.05 is statistically significant.

a

Wilcoxon signed ranks test.

b

Paired-samples T test, bold values are significant.