Skip to main content
. 2018 Aug;8(7):648–657. doi: 10.21037/qims.2018.08.05

Table 1. Comparison of radiation dose between RD-CT and LD-CT scans.

Parameters RD scans LD scans P value
Plain scans
   CTDIvol (mGy) 10.65±0.96 4.39±0.34 0.000
   Scan length chest (cm) 17.38±1.62 16.27±2.03 0.569
   Scan length abdomen (cm) 50.04±4.36 50.48±3.96 0.372
   ED (mSv) 10.58±1.28 4.32±0.73 0.000
Arterial phase
   CTDIvol (mGy) 10.65±0.96 4.42±0.47 0.000
   Scan length chest (cm) 17.38±1.62 16.27±2.03 0.569
   Scan length abdomen (cm) 25.85±2.65 26.73±2.40 0.625
   ED (mSv) 4.53±0.67 2.78±0.52 0.000
Portal vein phase
   CTDIvol (mGy) 10.65±0.96 4.51±0.39 0.000
   Scan length abdomen (cm) 46.90±3.86 47.35±3.92 0.783
   ED (mSv) 7.49±0.86 3.20±0.62 0.000
Delayed phase
   CTDIvol (mGy) 10.65±0.96 4.78±0.52 0.000
   Scan length abdomen (cm) 26.85±2.65 25.73±2.40 0.625
   ED (mSv) 4.29±0.54 1.84±0.22 0.000
In total
   CTDIvol (mGy) 42.60±3.84 18.10±1.72 0.000
   ED (mSv) 26.89±3.35 12.14±2.09 0.000

CTDIvol, CT dose index volume; ED, effective radiation dose; RD, routine dose computed tomography; LD, low dose; CT, computed tomography.