Table S3. Evaluation of pseudoaneurysm/abscess, vegetation, and dehiscence by aortic valve position and type.
Diagnostic performance | All prosthetic aortic valves | Bioprosthetic aortic valves | Mechanical prosthetic aortic valves | ||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
CT (n=75) | TEE (n=49) | P | CT (n=50) | TEE (n=35) | P | CT (n=25) | TEE (n=14) | P | |||
Pseudoaneurysm/abscess (%) | 1 | 1 | 0.68 | ||||||||
Sensitivity | 70 | 68 | 63 | 72 | 81 | 64 | |||||
Specificity | 74 | 67 | 73 | 80 | 75 | 33 | |||||
PPV | 89 | 86 | 85 | 90 | 94 | 78 | |||||
NPV | 45 | 40 | 46 | 53 | 43 | 20 | |||||
Vegetation (%) | 0.0008 | 0.016 | 0.04 | ||||||||
Sensitivity | 19 | 64 | 25 | 63 | 0 | 75 | |||||
Specificity | 97 | 71 | 94 | 73 | 100 | 70 | |||||
PPV | 89 | 75 | 89 | 83 | 0 | 50 | |||||
NPV | 48 | 60 | 41 | 47 | 60 | 88 | |||||
Dehiscence (%) | 1 | 1 | 0.47 | ||||||||
Sensitivity | 21 | 50 | 10 | 33 | 33 | 75 | |||||
Specificity | 95 | 97 | 93 | 97 | 100 | 100 | |||||
PPV | 57 | 83 | 25 | 67 | 100 | 100 | |||||
NPV | 78 | 88 | 80 | 88 | 73 | 91 |
CT, computed tomography; N/A, not applicable; NPV, negative predictive value; PPV, positive predictive value; TEE, transesophageal echocardiography.