Table III.

PERFORMANCE COMPARISON OF VOLTAMMETRIC DETECTOR ARRAYS

This work [27] [28] [29] [30] [31]
Process (μm) 0.5 0.5 0.35 0.35 0.18 0.065
Supply Voltage (V) 5.0 5.0 3.3 3.3 1.8 1.8
Pixel Count 64 100 1,024 1 200 4
Pixel Power (μW) 13.5 21 9,300 12.1 36
Pixel Area (mm2) 0.001 0.06 0.01 0.6 0.03 0.045
RMS Noise (pA) 0.443 7.2 0.540 120 0.480 50
Bandwidth (kHz) 10 11.5 0.13 7 0.110 10
Input Range (nA) ±1.5 ±110 ±1 ±300 ±0.2 ±2,560
Sweep Rate (V/s) 30 0.04 0.1 0.095 2.8 400
Cyclic Voltammetry Yes Yes Yes Yes Yes Yes
Amperometry Yes Yes Yes

open-input measurement

calculated from given information