Skip to main content
. 2018 Feb 16;3(1):e0032. doi: 10.2106/JBJS.OA.17.00032

TABLE V.

Mean Interobserver Reliability

Standard CT Analysis* Application Analysis* P Value
Expert group 0.86 0.93 >0.05
Fellow group 0.59 0.89 <0.05
Resident group 0.3 0.79 <0.01
Novice group 0.3 0.83 <0.01
*

The values are given as the interobserver correlation coefficient.