Table 1.

Methodology of blood pressure measurement in major hypertension trials

Study acronym [ref], year of publication Observer Device description Measurements, n Time interval between measurements Resting period Position(s) Arm Cuff Drug timinga
SHEP [4, 5], 1991 Trained, certified technician Random-zero sphygmomanometer Average of 4 readings (twice at each of the 2 visits) 30 s After 5 min of seated rest and 1–3 min of standing Seated and standing Right arm Appropriate size

STOP-H [6, 7], 1991 Nurse or doctor Mercury sphygmomanometer Average of 2 readings After 5 min in supine position and 1–3 min standing Supine and standing Appropriate size

MRC old [8], 1992 Nurse and/or doctor Random zero sphygmomanometer Average of the 2nd and the 3rd of 3 readings Seated

TOMHS [9, 10], 1993, 1991 Trained, certified, and monitored observer Random zero sphygmomanometer Average of 2 readings 30 s After 5 min of rest Seated Right arm Appropriate size Morning blood pressure 1–4 h after medication

SYST-EUR [11, 12], 1997, 1991 Mercury sphygmomanometer Average of 6 sitting and 6 standing readings (2 in each position at each of the 3 visits) After 2, 5, and 2 min of rest in supine, seated, and standing positions, respectively Seated, supine, and standing

SYST-China [13, 14], 1998 Physician Mercury sphygmomanometer Average of 6 readings (twice at each of the 3 visits) 1 min After 5 and 2 min of rest seated and standing, respectively Seated At troughb

HOT [15, 16], 1998, 2001 Oscillometric semiautomatic device 3 readings After 5 min of rest Seated

NICS-EH [17], 1999

CAPPP [18], 1999 Mercury sphygmomanometer Average of 3 readings Supine Appropriate size

NORDIL [19], 2000 Single reading at each of at least 2 visits After 10 min of rest Seated

INSIGHT [20, 21], 2000 Mercury sphygmomanometer Average of 3 readings After 5 min of rest At troughb

PROGRESS [22, 23], 2001, 1996 Trained observer Mercury sphygmomanometer Average of 2 readings 2 min After 5 min of rest Seated

IDNT [24], 2000 Seated

HOPE [25, 26], 2001, 2000 Mercury sphygmomanometer Average of 2 readings on each arm Arm with higher BP

Study acronym [ref], year of publication Observer Device description Measurements, n Time interval between measurements Resting period Position(s) Arm Cuff Drug timinga

LIFE [27, 28], 2002, 1997 Validated, calibrated manual manometer Average of 2 readings 1 min After 5 min of rest Seated and standing Right or left arm Appropriate size At trough (22–26 h)

ALLHAT [29, 30], 2002, 2001 Trained observer Average of 2 readings 30 s Seated

ANBP 2 [31, 32], 2003, 1997 Trained study nurse Mercury sphygmomanometer Average of the 2nd and 3rd of 3 readings if blood pressure difference <10/6 mm Hg between readings After 5 min of rest Seated Appropriate size

SCOPE [33, 34], 2003, 1999 Average of the 2nd and the 3rd of 3 readings 1 min After 5–10 min of rest Seated and standing Appropriate size

INVEST [35, 36], 2003, 1998 Mercury sphygmomanometer, calibrated aneroid manometer, or validated electronic device Average of 2 readings; additional readings if difference >5 mm Hg between readings 2 min After 5 min of rest Seated Right or left arm Appropriate size

VALUE [37], 2004 After 5 min of rest Seated At trough (24 h after the dose)

ASCOT-BPLA [39, 40], 2005, 2001 Semiautomated device (Omron HEM 705CP) Average of the 2nd and 3rd of 3 readings After 5 min of rest Seated All drugs taken no more than 24 h before study visits

FEVER [41], 2005 Mercury sphygmomanometer Average of 3 readings 1 min After 5 and 2 min of rest seated and standing, respectively Seated and standing Appropriate size

E-COST [42], 2005 Average of readings Seated At troughb

ADVANCE [43], 2007 Standardized automated (Omron HEM-705CP) Average of 2 readings After 5 min of rest Seated

AVOID [44], 2008 Mercury sphygmomanometer Average of 3 readings 2 min After 5 min of rest Appropriate size At troughb

ONTARGET [45, 46], 2008, 2004 Semiautomatic validated device (OMRON HEM-757) Average of 2 readings After 3 min of rest Seated

ACCOMPLISH [47, 48], 2008, 2004 Average of 3 readings 2 min After 5 min of rest Seated

Study acronym [ref], year of publication Observer Device description Measurements, n Time interval between measurements Resting period Position(s) Arm Cuff Drug timinga

JATOS [49], 2005 Sphygmomanometer Average of at least 2 readings per visit After 5–10 min of rest Seated

CASE-J [50], 2008 Average of 2 readings Seated

HIJCREATE [51], 2009 Mercury sphygmomanometer After 5 min of rest Seated

ACCORD BP [52, 53], 2010, 2007 Automated blood pressure monitor (Omron 907) Average of 3 readings Seated

COPE [54], 2011 Physician Average of 2 stable readings 1–2 min After 5 min of rest Seated

OSCAR [55, 56], 2012, 2009 Mercury or automatic sphygmomanometer Single reading at 2 different visits Seated

NAGOYA HEART [57], 2010 Single reading at each of at least 2 visits

SPRINT [58], 2017 Unattended Automated manometer (Omron 907) Average of 3 readings 1 min After 5 min of rest Seated Proper cuff size

HOPE-3 [59, 60], 2016 Automatic blood pressure monitor (Omron HEM-711DLXCAN) or mercury sphygmomanometer Average of 2 readings At least 1 min After 5 min of rest Seated Right arm Evenly tight
a

Timing of the blood pressure measurement in relation to the last medication dosage.

b

”Trough” usually refers to blood pressure measured 20–26 h after the last study medication was taken.