Skip to main content
. Author manuscript; available in PMC: 2019 Dec 1.
Published in final edited form as: Int J Hyperthermia. 2018 Feb 22;34(8):1213–1224. doi: 10.1080/02656736.2018.1438672

Table 3.

Descriptions of sonication parameter–dependent lesions in ex vivo porcine liver, kidney, and cardiac muscle tissues.

Parameter Set Liver Kidney Cardiac Muscle
A Paste-like Paste-like Vacuolated + Mild Thermal
B Paste-like Paste-like + Mild Thermal Vacuolated + Thermal
C Solid Thermal Mild Paste-like Paste-like
D Vacuolated Mild Vacuolated Vacuolated
E Solid Thermal + Mild Paste-like Vacuolated Paste-like
F Solid Thermal Paste-like Mild Vacuolated + Thermal