Skip to main content
. 2018 Jun 5;19:1361–1381. doi: 10.1016/j.dib.2018.05.145

Table 2.

Percentage distribution of ICC(2,1) values for the four statistical models.

Model 1: Within-Session Reproducibility
Model 2: Between-Session Reproducibility
1 Rep 10 Rep 1 Rep 10 Rep
ICC(2,1)
ICC(2,1)
ICC(2,1)
ICC(2,1)
<.60 .60 –.69 ≥.70 <.60 .60–.69 ≥.70 <.60 .60–.69 ≥.70 <.60 .60–.69 ≥.70
% % % % % % % % % % % %
End_nofuz 31.67 13.73 54.60 24.22 11.07 64.71 52.30 19.08 28.62 47.93 17.45 34.62
End_fuz 21.02 12.46 66.52 16.60 8.93 74.47 44.91 15.94 39.15 38.87 18.21 42.92
Vis_nofuz 14.11 8.56 77.34 11.76 7.64 80.60 34.42 15.92 49.67 30.57 16.80 52.63
Vis_fuz 9.31 4.65 86.04 8.60 4.80 86.60 21.33 12.56 66.11 20.63 11.63 67.74
Model 3: Within-Session Reproducibility
Model 4: Between-Session Reproducibility
12ch 32ch 12ch 32ch
ICC(2,1)
ICC(2,1)
ICC(2,1)
ICC(2,1)
<.60 .60 –.69 ≥.70 <.60 .60 –.69 ≥.70 <.60 .60 –.69 ≥.70 <.60 .60 –.69 ≥.70
% % % % % % % % % % % %
End_nofuz 15.03 7.80 77.18 12.77 7.46 79.77 36.39 17.91 45.69 29.37 14.63 56.01
End_fuz 11.90 6.89 81.21 10.99 5.33 83.68 33.63 17.06 49.31 25.18 12.59 62.23
Vis_nofuz 8.26 5.34 86.40 7.94 5.26 86.80 26.81 14.81 58.37 21.18 12.72 66.10
Vis_fuz 6.47 3.59 89.94 4.42 3.01 92.57 18.22 10.87 70.91 16.30 9.59 74.10

For each combination of reconstruction repetition or type of head-coil with streamline selection variant, numbers in cells refer to the percentage of intra-class correlation coefficient (ICC) type ICC(2,1) values falling within each of the following three categories: ICC(2,1) <.60, corresponding to low reproducibility; ICC(2,1) between .60 and .69, corresponding to marginal reproducibility; ICC(2,1) ≥.70, corresponding to adequate reproducibility or higher. 1 Rep, 1 reconstruction repetition; 10 Rep, 10 reconstruction repetitions; 12ch, 12-channel head-coil; 32ch, 32-channel head-coil; end_nofuz, endpoint_nofuzzy; end_fuz, endpoint_fuzzy; vis_nofuz, visiting_nofuzzy; and vis_fuz, visiting_fuzzy streamline selection.