Skip to main content
. 2018 Jul 2;19:2119–2125. doi: 10.1016/j.dib.2018.06.096
Subject area Chemistry, Materials Science
More specific subject area Electro-optic field sensors
Type of data Crystal data and structure refinement, NMR spectrum, tables and figure
How data was acquired NMR recorded in DMSO using Bruker Spectrometers operating at 400 MHz.
UV-Visible and fluorescence spectra recorded with JASCO spectrometers.
Single crystals X-ray structural analysis performed on a BrukerNoniusKappaCCD diffractometer equipped with Oxford Cryostream apparatus.
Data format Raw data and their elaborations
Experimental factors The data concerns structural information, UV/Vis calculation and some spectroscopic raw data
Experimental features Elaboration of X-ray diffraction data and UV/Vis curves
Data source location Naples, Italy
Data accessibility Data is within this article