Conceptual demonstration of sub-wavelength localization using deconvolution on synthetic data. (a) PSF of the imaging system. FWHM is assumed as 150 µm. (b) The locations of the two neighboring targets (Ground truth). Two targets are positioned 70 µm apart. (c) The synthetic signal received from two targets is shown in (b) using the imaging system with PSF shown in (a). This signal is modeled as a received signal in the imaging system whose has PSF shown in (a). Two targets cannot be separated in the image due to their distance is shorter than the spatial resolution of the imaging system. (d) Deconvolution results of received signal shown in (c) using the system PSF shown in (a). Two targets are distinctly identified. (e) The synthetic signal received from two targets when noise is added is shown in (b) using the same imaging system. (f) Deconvolution results of (e), where two targets are clearly identified with minimal interference due to noise.