Skip to main content
. 2018 Sep;128(3):485–491. doi: 10.1016/j.radonc.2018.04.018

Supplementary Fig. 2.

Supplementary Fig. 2

A: Bland Altman plot for mean ADC values in PET-derived ROIs measured with RT and diagnostic setup. Graph shows difference between two measurements plotted against their average. Solid lines indicate the mean of differences and the limits of agreement (mean ± 1.96 × SD). Corresponding confidence intervals are shown as gray-shaded areas. B: relative difference of ADC between both scans. C, D: ADC map of one patient (#06, axial slice) acquired with RT and diagnostic setup, respectively. ROI structures in lesions are shown in color. Note the difference in patient positioning between both scans.